Apple A1267 Specifikace Strana 63

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 92
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 62
LED Cinema Display (24-inch) Take Apart — Blower 63
2010-02-08
Replacement
Reassembly is an exact
reversal of the steps
above, with 3 notes:
Note 1: The ambient
temp sensor cable (922-
8672) must extend exactly
1cm from the plastic
retaining ring on the
blower casing so that it
will sit the proper distance
from the rear housing
when installed.
Incorrect sensor
placement can lead to
false temperature readings
and unusual fan behavior.
Note 2: Ensure the
pressure wall section
attached to the blower ts
securely into foam on rear
housing for a snug t.
Air leaks in the pressure
wall can lead to
temperature and/or noise
issues with the unit.
Note 3: If you have
trouble reconnecting
cables to the logic board,
unscrew and ip over
logic board for better
access to connectors.
Zobrazit stránku 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 91 92

Komentáře k této Příručce

Žádné komentáře