Apple WebObjects 3.5: Serving Uživatelský manuál Strana 19

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 37
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 18
Serving WebObjects
20
application’s .woa directory and execute WODefaultApp, which is located in
NeXT_ROOT
/NextLibrary/Executables.
-debug ON|OFF
Sets whether the application prints messages to standard output during startup.
By default, this option is ON. If this option is ON, the application prints mes-
sages such as the following:
Aug 22 18:08:46 WODefaultApp[423] Application Path:
/NextDeveloper/Examples/WebObjects/HelloWorld
Aug 22 18:08:50 WODefaultApp[423] Application Base URL:
/WebObjects/Examples/HelloWorld
Aug 22 18:08:50 WODefaultApp[423] Application Name:
Examples/HelloWorld
Aug 22 18:08:51 WODefaultApp[423] Reading WebServer configuration
from /NextLibrary/WOAdaptors/Configuration/WebServerConfig.plist.
Aug 22 18:08:51 WODefaultApp[423] Opening application's URL in
Browser:
http://localhost/cgi-bin/WebObjects/Examples/HelloWorld
Aug 22 18:08:54 WODefaultApp[423] waiting for requests...
-browser ON|OFF
Sets whether the application automatically starts up the web browser. The
default is ON. If this option is ON, the browser automatically opens a new
browser window (starting up the browser if necessary) with the WebObjects
application’s URL.
-m ON|OFF
Enables or disables monitoring. The default is ON. If this option is ON and you
manually start up an application, the application tries to find a running Monitor.
If it finds one, Monitor can automatically locate the application and display
information about it, provided an instance number is given with the adaptor’s
-n
option as described below.
-mhost hostname | subnet
The application tries to find a running Monitor on the machine named hostname
instead of on the local machine. If
subnet is used, the application looks for a run-
ning Monitor in its network subnet.
-c
Requests that the application cache component definitions (templates) instead
of reparsing HTML and declaration files upon each new HTTP request. By
default, applications do not cache component definitions. This setting ensures
that during development of scripted applications programmers can modify a
component’s logic and see the result without having to relaunch the application.
If you are deploying applications, however, you should turn on component-defi-
nition caching by specifying this flag when you launch the application.
Zobrazit stránku 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 36 37

Komentáře k této Příručce

Žádné komentáře

Agilent Technologies Multimeters user manuals

Starting on B

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
B1542A
User Manual   B1500A brochure 95.p65, 20 pages
User Manual   Agilent B1542A - Agilent Technologies [en] , 4 pages
B2201A
User's Guide   Agilent Technologies B2201A User`s guide, 230 pages
B2902
User's Guide   Agilent Technologies B2902 User`s guide, 232 pages